Mon-Fri 9:00-18:00
Order a call
Products
Request a CO
Поиск по сайту Каталог Контакты нашей компании Контакты Позвонить нам по телефону Связаться Объекты выполненные нашей компанией Объекты

from 43 340 rub.
01

Features and prices

Емкость
Емкость
Product name
2 м3
2 м3
2 м3
3 м3
3 м3
3 м3
4 м3
4 м3
4 м3
5 м3
5 м3
5 м3
6 м3
6 м3
6 м3
8 м3
8 м3
8 м3
10 м3
10 м3
10 м3
12 м3
12 м3
12 м3
15 м3
15 м3
15 м3
20 м3
20 м3
20 м3
30 м3
30 м3
30 м3
40 м3
40 м3
40 м3
50 м3
50 м3
60 м3
60 м3
80 м3
100 м3
150 м3
200 м3
Diameter D, mm
1 000
1 100
1 200
1 100
1 200
1 400
1 200
1 400
1 500
1 400
1 500
1 600
1 400
1 500
1 600
1 500
1 600
1 800
1 500
1 600
1 800
1 600
1 800
2 000
1 600
1 800
2 000
1 800
2 000
2 300
2 000
2 300
2 500
2 300
2 500
3 200
2 500
3 200
2 500
3 200
3 200
3 200
3 600
4 200
Length L, mm
2 700
2 300
1 950
3 350
2 800
2 150
3 800
2 800
2 500
3 450
3 050
2 650
4 100
3 600
3 150
4 750
4 150
3 300
5 900
5 150
4 100
6 100
4 850
4 050
7 600
6 050
5 000
8 000
6 600
5 050
9 750
7 450
6 350
9 850
8 400
5 400
10 450
6 650
12 500
7 900
10 400
12 500
15 100
15 000
Diameter of the inlet/outlet pipe N, mm
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
according to the project
Dry container weight, kg
70
70
70
90
90
114
120
140
160
160
180
200
180
200
230
240
280
320
290
330
370
380
430
440
460
510
520
650
650
790
900
1 070
1 120
1 350
1 390
1 900
1 670
2 490
2 220
2 940
3 520
4 010
8 300
9 500
Weight of the container with water, kg
2 070
2 070
2 070
3 090
3 100
3 114
4 120
4 140
4 160
5 160
5 180
5 200
6 180
6 200
6 230
8 240
8 280
8 320
10 290
10 330
10 370
12 380
12 430
12 440
15 460
15 510
15 520
20 650
20 650
20 790
30 900
31 070
31 120
41 350
41 390
41 900
51 670
52 490
62 220
62 940
83 520
104 010
158 300
209 500
02

General description

Storage tanks are used in local drainage systems of residential households as a reservoir for buffering wastewater (stormwater, sewage), as well as at industrial enterprises to collect industrial wastewater.

    The use of storage tanks for collecting storm and domestic wastewater is relevant in the following cases:
  • if it is impossible to organize septic tanks without the use of tanks due to difficult soil conditions;
  • at high values of the level of groundwater;
  • in other cases, when soil treatment of effluents is impossible.

For industrial wastewater, the use of storage tanks is desirable, and serves as the primary stage of wastewater treatment in engineering treatment networks.

Horizontal
The most common type of storage tanks due to its simplified installation and lighter design.

Vertical
The advantage of this type is a small footprint, which allows them to be placed even in cramped conditions, as well as simplified scalability (the ability to add capacity, if necessary, into a single system).

Underground installation
For underground tanks, an essential requirement is the rigidity of the structure in order to exclude mechanical deformation under additional loads from the earth masses. Also, the structure and composition of the material of the tank must ensure resistance to corrosion, the effects of biological organisms, tightness.

Ground installation
For ground structures, wind and snow loads must be taken into account. The design of the storage tanks made of fiberglass must be taken into account in their production from the point of view of the distribution and the method of applying reinforcing material, for the correct distribution of the intended loads. Such parameters can be set individually or the standard requirements will be taken into account in the case of serial production.

    The main structural elements of fiberglass storage tanks are:
  • body;
  • technical well complete with ladder and cover.
    Taking into account the type of installation, purpose and design (horizontal / vertical), storage tanks can be completed additionally:
  • flange connections;
  • fastenings for anchors;
  • filters and pumps;
  • an operating site for routine maintenance;
  • emergency automation system;
  • thermal insulation;
  • heating cable;
  • lodgments or anchor bolts.
4 factories

in Russia, with an area of 15,000 m2

17 years

in the market of water treatment and wastewater disposal

4 000+

products are released annually

03

Product benefits

  • the use of modern equipment;
  • cooperation with European suppliers;
  • more than 17 years on the market;
  • three production sites, which allows us to quickly fulfill orders and significantly reduce logistics costs.
04

Applications

1 / 1

For designers
Documentation
Questionnaires
Reviews
Press
Still have questions?

Fill out the feedback form to get a consultation

Drop you files here
Drop